  Datasheet File OCR Text:
  owners manual self-priming centrifugal pump 3621 1199 asb ds3 series installation/operation/parts for further operating, installation, or maintenance assistance: call 888-782-7483 ? 2012 pentair, inc. all rights reserved. s536 (11/08/12) 293 wright street, delavan, wi 53115 www. st a - rite .c om ph: 888-782-7483 free datasheet http:///
safety 2 read and follow safety instructions! this is the safety alert symbol. when you see this symbol on your pump or in this manual, look for one of the following signal words and be alert to the potential for personal injury. warns about hazards that will cause serious personal injury, death or major property damage if ignored. warns about hazards that can cause serious personal injury, death or major property damage if ignored. warns about hazards that will or can cause minor personal injury or property damage if ignored. the label notice indicates special instructions which are important but not related to hazards. carefully read and follow all safety instructions in this manual and on pump. keep safety labels in good condition. replace missing or damaged safety labels. california proposition 65 warning this product and related accessories contain chemicals known to the state of california to cause cancer, birth defects or other reproductive harm. g eneral s afety do not touch an operating motor. modern motors can operate at high temperatures. to avoid burns when servicing pump, allow it to cool for 20 minutes after shut-down before handling. pump is designed as a lawn sprinkler only. to avoid heat built-up, over pressure hazard and possible injury, do not use in a pressure tank (domestic water) system. do not use as a booster pump; pressurized suction may cause pump body to explode. do not allow pump or piping system to freeze. freezing can damage pump and pipe, may lead to injury from equipment failure and will void warranty. pump water only with this pump. periodically inspect pump and system components. wear safety glasses at all times when working on pumps. keep work area clean, uncluttered and properly lighted; store properly all unused tools and equipment. keep visitors at a safe distance from the work areas. make workshops childproof; use padlocks and master switches; remove starter keys. warning hazardous pressure! install pressure relief valve in discharge pipe. release all pressure on system before working on any component. warning hazardous voltage. can shock, burn, or cause death. ground pump before connecting to power supply. wire motor for correct voltage. see electri cal section of this manual and motor nameplate. ground motor before connecting to power supply. meet national electri cal code, canadian elec tri cal code, and local codes for all wiring. follow wiring instructions in this manual when connecting motor to power lines. electrical s afety
table of contents 3 thank you for purchasing a top quality, factory tested pump. page safety ................................................................................................................... 2 warranty..............................................................................................................3 installation ........................................................................................................ 4-5 electrical .............................................................................................................. 6 operation ............................................................................................................ 7 maintenance ................................................................................................... 8-10 troubleshooting ................................................................................................. 11 repair parts ...................................................................................................... 12 limited warranty sta-rite warrants to the original consumer purchaser (purchaser or you) of the products listed below, that they will be free from defects in material and workmanship for the warranty period shown below. product warranty period water systems products jet pumps, small centrifugal pumps, submersible pumps and related accessories whichever occurs first: 12 months from date of original installation, or 18 months from date of manufacture pro-source? composite tanks 5 years from date of original installation pro-source? steel pressure tanks 5 years from date of original installation pro-source? epoxy-lined tanks 3 years from date of original installation sump/sewage/effluent products 12 months from date of original installation, or 18 months from date of manufacture our warranty will not apply to any product that, in our sole judgement, has been subject to negligence, misapplication, improper installation, or improper maintenance. without limiting the foregoing, operating a three phase motor with single phase power through a phase converter will void the warranty. note also that three phase motors must be protected by three-leg, ambient compensated, extra-quick trip overload relays of the recommended size or the warranty is void. your only remedy, and sta-rites only duty, is that sta-rite repair or replace defective products (at sta-rites choice). you must pay all labor and shipping charges associated with this warranty and must request warranty service through the installing dealer as soon as a problem is discovered. no request for service will be accepted if received after the warranty period has expired. this warranty is not transferable. sta-rite shall not be liable for any consequential, incidental, or contingent damages whatsoever. the foregoing warranties are exclusive and in lieu of all other express and implied warranties, including but not limited to the implied warranties of merchantability and fitness for a particular purpose. the foregoing warranties shall not extend beyond the duration expressly provided herein. some states do not allow the exclusion or limitation of incidental or consequential damages or limitations on the duration of an implied warranty, so the above limitations or exclusions may not apply to you. this warranty gives you specific legal rights and you may also have other rights which vary from state to state. this limited warranty is effective june 1, 2011 and replaces all undated warranties and warranties dated before june 1, 2011. sta-rite industries 293 wright street ? delavan, wi u.s.a. 53115 phone: 1-888-782-7483 ? fax: 1-800-426-9446 ? web site: sta-rite.com
installation 4 b efore y ou i nstall y our p ump notice: well must not be more than 20 depth to water. 1. long runs and many fittings increase friction and reduce flow. locate pump as close to well as possible: use as few elbows and fittings as possible. 2. be sure well is clear of sand. sand will plug the pump and void the warranty. 3. protect pump and all piping from freezing. freezing will split pipe, damage pump and void the warranty. check locally for frost protection requirements (usually pipe must be 12 below frost line and pump must be insulated). 4. be sure all pipes and foot valve are clean and in good shape. 5. no air pockets in suction pipe. 6. no leaks in suction pipe. use ptfe pipe thread sealant tape to seal pipe joints. 7. unions installed near pump and well will aid in servicing. leave room use wrenches. 8. pump body may explode if used as a booster pump. do not use in a booster appli cation. w ell p ipe i nstallation notice: use the installation method below which matches your well type. cased well installation 1. inspect foot valve to be sure it works freely. inspect strainer to be sure it is clean. 2. connect foot valve and strainer to the first length of suction pipe and lower pipe into well. add sections of pipe as needed, using ptfe pipe thread sealant tape on male threads. be sure that all suction pipe is leakproof or pump will lose prime and fail to pump. install foot valve 10 to 20 feet below the lowest level to which water will drop while pump is operating (pumping water level). your well driller can furnish this in formation. 3. to prevent sand and sediment from entering the pumping system, the foot valve/strainer should be at least 5 feet above the bottom of the well. 4. when the proper depth is reached, install a sanitary well seal over the pipe and in the well casing. tighten the bolts to seal the casing. 5. when using a foot valve, a priming tee and plug as shown in figure 1 are recommended. dug well installation same as cased well installation. driven point installation 1. connect the suction pipe to the drive point as illustrated in figure 2. keep horizontal pipe run as short as possible. use ptfe pip thread sealant tape on male pipe threads. multiple well points may be necessary to provide sufficient water to pump. 2. install a check valve in horizontal pipe. flow arrow on check valve must point toward pump. suction pipe foot valve priming plug priming tee standing water level (pump off) drawdown water level (pump on) 10-20' (3-6 m) 20' (6 m) max. at least 5 feet (1.5 m) 828 0993 chec k v alv e steel dr iv e pipe driv e coupling driv en point 745 0993 figure 1: cased/dug well installation figure 2: driven point installation
installation 5 horizontal piping from well to pump 1. never install a suction pipe that is smaller than the suction port of the pump. 2. to aid priming on well point installations, install a line check valve as shown in figure 2. be sure check valve flow arrow points toward pump. discharge pipe sizes 1. if increasing discharge pipe size, install reducer in pump discharge port. do not increase pipe size by stages. 2. when the pump is set away from the points of water use, the discharge pipe size should be increased to reduce pressure losses caused by friction. ? up to 100 run: same size as pump discharge port. ? 100 to 300 run: increase one pipe size. ? 300 to 600 run: increase two pipe sizes. lawn sprinkling application this pump is designed for lawn sprinkling. it is de signed to deliver plenty of water at full sprinkler pres sure. it can pump from a pond, cistern or well points. pump discharge can be divided to supply two (2) or more sprinkler systems. a suggested multiple dis charge to service is shown in figure 3. do not use in a pressure tank or booster pump application. pump installation notice: use only ptfe pipe thread sealant tape for making all threaded connections to the pump itself. do not use pipe joint compounds on plastic pumps: they can react with the plastic in the pump components. make sure that all pipe joints in the suction pipe are air tight as well as water tight. if the suction pipe can suck air, the pump will not be able to pull water from the well. 1. bolt pump to solid, level foundation. 2. support all piping connected to the pump. 3. wrap 1-1/2 to two layers of ptfe pipe thread sealant tape clockwise (as you face end of pipe) on all male threads being attached to pump. 4. tighten joints hand tight plus 1-1/2 turns. do not overtighten. notice: install pump as close to well head as poss ible. long piping runs and many fittings create friction and reduce flow. notice: for long horizontal pipe runs, install a priming tee between check valve and well head as shown in figure 1. for driven point installations, install a check valve as shown in figure 2. be sure check valve flow arrow points toward pump. use schedule 80 or iron pipe. see well pipe in stalla tion for more information. 20 100 80 60 40 1909 0997 ds3 figure 3: multiple discharge 3023 0997 ds3 figure 4: bolt pump down 20 100 80 60 40 3024 0997 ds3 figure 5: independently support all piping attached to pump
electrical 6 connection diagram for dual voltage, single-phase motors. your dual-voltage motors terminal board (under the motor end cover) will match one of the diagrams below. follow that diagram if necesary to convert motor to 115 volt power. connect power supply wires to l1 and l2. for 3-phase motors, or if motor does not match these pictures, follow the connection diagram on the motor nameplate. m otor s witch s ettings dual-voltage motors (motors that can operate at either 115 or 230 volts), are set at the factory to 230 volts. do not change motor voltage setting if line voltage is 230 volts, or if you have a single voltage motor. notice: never wire a 115 volt motor to a 230 volt line. r emove m otor e nd c over if you have a dual-voltage motor, and will connect it to 115 volts, follow the procedure below. you will need to remove the motor end cover to change the voltage setting. your motor terminal board (located under the motor end cover) should look like one of those below. p lug t ype v oltage s elector to change to 115 volts: 1. make sure power is off. 2. pull the plug straight up. 3. move and attach the plug at the 115 volt position. the plug will now cover 2 metal tabs. the arrow on the plug will point to 115v. 4. attach the power lead wires to the power lead terminals. make sure the wires are secure. 5. attach the ground wire to the green ground screw 6. reinstall the motor end cover go to wiring connections below. d ial t ype v oltage s elector to change to 115 volts: 1. make sure power is off. 2. turn the dial counter-clockwise until 115 shows in the dial window. 3. attach the power lead wires to the power lead terminals. make sure the wires are secure. 4. attach the ground wire to the green ground screw 5. reinstall the motor end cover go to wiring connections below. hazardous voltage. can shock, burn, or cause death. disconnect power to motor before working on pump or motor. ground motor before connecting to power supply. wiring connections ground motor before connecting to electrical power supply. failure to ground motor can cause severe or fatal electrical shock hazard. do not ground to a gas supply line. to avoid dangerous or fatal electrical shock, turn off power to motor before working on electrical connections. supply voltage must be within 10% of nameplate voltage. incorrect voltage can cause fire or damage motor and voids warranty. if in doubt consult a licensed electrician. use wire size specified in wiring chart, page 7. if possible, connect pump to a separate branch circuit with no other appliances on it. wire motor according to diagram on motor nameplate. if nameplate diagram differs from diagrams above, follow nameplate diagram. 1. install, ground, wire and maintain this pump in accordance with electrical code requirements. consult your local building inspector for information about codes. figure 6: removing motor end cover figure 7: voltage set to 230 volts, plug type motor end cover end cover screws 4693 voltage change plug ground screw po wer lead te rminals 4694 figure 8: voltage set to 230 volts, dial type voltage change dial ground screw po wer lead te rminals 4695
electrical / operation 7 2. provide a correctly fused disconnect switch for protection while work- ing on motor. consult local or national electrical codes for switch requirements. 3. disconnect power before servicing motor or pump. if the disconnect switch is out of sight of pump, lock it open and tag it to prevent unex- pected power application. 4. ground the pump permanently using a wire of the same size as that specified in wiring chart, below. make ground connection to green grounding terminal under motor canopy marked grd. or . 5. connect ground wire to a grounded lead in the service panel or to a metal underground water pipe or well casing at least 10 feet long. do not connect to plastic pipe or insulated fittings. 6. protect current carrying and grounding conductors from cuts, grease, heat, oil, and chemicals. 7. connect current carrying conductors to terminals l 1 and l 2 under motor canopy. when replacing motor, check wiring diagram on motor nameplate against figure 6. if the motor wiring diagram does not match either diagram in figure 6, follow the diagram on the motor. important: 115/230 volt single phase models are shipped from factory with motor wired for 230 volts. if power supply is 115 volts, remove motor canopy and reconnect motor as shown in figure 6. do not try to run motor as received on 115 volt current. 8. motor has automatic internal thermal overload protection. if motor has stopped for unknown reasons, thermal overload may restart it unexpect- edly, which could cause injury or property damage. disconnect power before servicing motor. 9. if this procedure or the wiring diagrams are confusing, consult a licensed electrician. priming the pump notice: priming refers to the pump expelling all air in the system and begin- ning to move water from its source out into the system. it does not refer only to pouring water into the pump (although pouring water in is usually the first step). notice: never run pump dry. running pump with out water in it will damage seals and can melt impeller and diffuser. to prevent damage, fill pump with water before starting. 1. remove priming plug (figure 9). 2. make sure suction and discharge valves and any hoses on discharge side of pump are open. wiring chart C recommended wire and fuse sizes distance in feet(meters) from motor to supply 0 - 50 51 - 100 101 - 200 201 - 300 max. load volts/hz branch fuse (0 - 15) (31 - 61) (62 - 91) (92 - 122) model hp amp phase rating amp awg wire size (mm 2 ) ds3he-01 1 14.8/7.4 115/230/60/1 20/15 12/14 (3/2) 12/14 (3/2) 8/14 (8.4/2) 6/14 (14/2) ds3he3-01 1 3.6/1.8 230/460/60/3 15/15 14/14 (2/2) 14/14 (2/2) 14/14 (2/2) 14/14 (2/2) DS3HF-01 1-1/2 20/10 115/230/60/1 25/15 10/14 (5.5/2) 10/14 (5.5/2) 8/14 (8.4/2) 6/12 (14/3) ds3hf3-01 1-1/2 4.7/2.35 230/460/60/3 15/15 14/14 (2/2) 14/14 (2/2) 14/14 (2/2) 14/14 (2/2) ds3hg-01 2 24/12 115/230/60/1 30/15 12/14 (3/2) 10/14 (5.5/2) 6/14 (14/2) 6/12 (14/3) ds3hg3-01 2 5.8/2.9 230/460/60/3 15/15 14/14 (2/2) 14/14 (2/2) 14/14 (2/2) 14/14 (2/2) ds3hhg-01 2-1/2 26/12 115/230/60/1 35/15 12/14 (3/2) 10/14 (5.5/2) 6/14 (14/2) 6/8 (14/8.4) ds3hhg3-01 2-1/2 6.9/3.45 230/460/60/3 15/15 14/14 (2/2) 14/14 (2/2) 14/14 (2/2) 14/14 (2/2) 3025 0997 ds3 20 100 80 60 40 figure 9: remove priming plug and fill pump before starting 750 0993 figure 10: run ten minutes or less 3026 0997 ds3 20 100 80 60 40 figure 11: do not run pump with discharge shut-off
maintenance 8 3. fill pump and suction pipe with water. 4. replace priming plug, using ptfe pipe thread sealant tape on thread; tighten plug. notice: if a priming tee and plug have been provided for a long horizontal run, be sure to fill suction pipe through this tee and replace plug. (dont forget to ptfe pipe thread sealant tape the plug.) 5. start pump: water should be produced in 10 minutes or less, the time depending on depth to water (not more than 20) and length of horizontal run (10 of horizontal suction pipe = 1 of vertical lift due to friction losses in the pipe). if no water is produced within 10 minutes, stop pump, release all pressure, remove priming plug, refill and try again. hazardous pressure and risk of ex plo sion and scalding. if pump is run con ti nu ously at no flow (that is, with discharge shut off or without priming), water may boil in pump and piping system. under steam pressure, pipes may rupture, blow off of fittings or blow out of pump ports and scald anyone near. to prevent explosion, do the following: a. be sure discharge (valve, pistol grip hose nozzle, etc.) is open whenever pump is running. b. if pump fails to produce water when attempting to prime, release all pressure, drain pump and refill with cold water after every two attempts. c. when priming, monitor pump and piping tempera ture. if pump or piping begin to feel warm to the touch, shut off pump and allow system to cool off. release all pressure in system and refill pump and piping with cold water. pump and piping need not be disconnected to repair or replace motor or seal (see figure 13). if motor is replaced, replace the shaft seal (key no. 5, page 12). keep one on hand for future use. be sure to prime pump before starting. notice: check motor label for lubrication instructions. the mechanical shaft seal in the pump is water lubricated and self-adjusting. notice: drain pump when disconnecting from service or when it might freeze. pump disassembly 1. disconnect power to motor. notice: mark wires for correct assembly. 2. remove capscrews holding seal plate to pump body. motor assembly and seal plate can now be pulled away from pump body (figure 13). care fully remove gasket. cleaning/replacing impeller notice: first, follow instructions under pump dis assembly. 1. remove screws fastening diffuser to seal plate; re move diffuser (see figure 14). exposed impeller can now be cleaned. 2. if impeller must be replaced, loosen two machine screws and remove motor canopy (see figure 15). 3. capacitor voltage may be hazardous. to discharge capacitor, hold insulated handle screwdriver by the handle and short capacitor terminals together (see figure 15). do not touch metal screwdriver blade or capacitor terminals. if in doubt, consult a qualified electrician. on off 1060b 0997 figure 12: disconnect power 20 100 80 60 40 3027 0997 ds3 figure 13: slide motor back 3028 0997 figure 14: remove diffuser figure 15: hold shaft 739 0993 to avoid electrical shock hazard, use insulated-handle screwdriver to short capacitor terminals as shown. 739 0993
maintenance 9 4. unscrew capacitor clamp and remove capacitor. do not disconnect capacitor wires to motor. 5. slide 7/16 open end wrench in behind spring loaded switch on motor end of shaft; hold motor shaft with wrench on shaft flats and unscrew impeller screw (if used) by turning clockwise (left hand thread) when looking into eye of impeller. 6. unscrew impeller while holding shaft by turning counterclockwise while looking into eye of impeller. 7. to reinstall, reverse steps 1 through 6. 8. see directions under pump reassembly, page 10. removing old seal 1. follow instructions under pump disassembly. 2. follow steps 2 through 5 under cleaning/replacing impeller. 3. remove rotating half of seal by placing two screw drivers under seal ring and carefully prying up (figure 16). 4. remove nuts from studs holding seal plate to motor. carefully slide seal plate off of shaft. notice: be sure you do not scratch or mar shaft; if shaft is marred, it must be dressed smooth with fine emery or crocus cloth before installing new seal. do not reduce shaft diameter! 5. place seal plate half face down on flat surface and tap out stationary half of seal (see figure 17). installing new seal 1. clean seal cavity in seal plate. 2. wet outer edge of rubber cup on ceramic seat with liquid soap. be sparing! 3. put clean cardboard washer on seal face. with thumb pressure, press ceramic seal half firmly and squarely into seal cavity (see figure 18). polished face of ceramic seat is up. if seal will not seat correctly, remove, placing seal face up on bench. reclean cavity. seal should now seat correctly. 4. if seal does not seat correctly after recleaning cavity, place a cardboard washer over polished seal face and carefully press into place using a piece of standard 3/4 pipe as a press. notice: be sure you do not scratch seal face. 5. dispose of cardboard washer and recheck seal face to be sure it is free of dirt, foreign particles, scratches and grease. 6. inspect shaft to be sure it is free of nicks and scratches. 7. reassemble pump body half to motor flange. be sure it is right side up. 8. apply liquid soap sparingly (one drop is sufficient) to inside diameter of rotating seal member. 9. slide rotating seal member (carbon face first) onto shaft until rubber drive ring hits shaft shoulder. notice: be sure not to nick or scratch carbon face of seal when passing it over threaded shaft end or shaft shoulder. the carbon surface must remain clean or short seal life will result. 3029 0997 figure 16: remove seal plate 3030 0997 figure 17: tap out seal 3031 0997 figure 18: press in new seal 1072 0697 ceramic face carbon face be careful that motor shaft shoulder... ...does not damage seal face figure 19: protect seal faces
maintenance 10 10. hold motor shaft with 7/16 open end wrench on shaft flats and screw impeller onto shaft. be sure you do not touch capacitor terminals with body or any metal object. tightening impeller will automatically locate seal in correct position. 11. replace impeller screw (if used) by turning counterclockwise (left-hand thread) into end of shaft. 12. remount diffuser on seal plate with two screws. 13. follow instructions under pump reassembly. pump reassembly 1. clean gasket surfaces on pump body and seal plate; install new gasket. 2. slide motor/seal plate assembly into pump body. secure with capscrews. 3. replace base mounting bolts. 4. replace motor wiring; close draincock. 5. prime pump according to instructions. see opera tion. 6. check for leaks. 20 100 80 60 40 3027 0997 ds3 figure 21: assemble pump figure 20: hold shaft 739 0993 to avoid electrical shock hazard, use insulated-handle screwdriver to short capacitor terminals as shown.
troubleshooting 11 symptom possible cause(s) corrective action motor will not run disconnect switch is off be sure switch is on fuse is blown replace fuse starting switch is defective replace starting switch wires at motor are loose, refer to instructions on wiring. check and tighten all wiring. disconnected, or wired incorrectly capacitor voltage may be hazardous. to discharge capacitor, hold insulated handle screwdriver by the handle and short capacitor terminals together. do not touch metal screwdriver blade or capacitor terminals. if in doubt, consult a qualified electrician. motor runs hot and motor is wired incorrectly refer to instructions on wiring overload kicks off voltage is too low check with power company. install heavier wiring if wire size is too small (see electrical, page 6) motor runs but no *pump in new installation did in new installation: water is delivered not pick up prime through: 1. improper priming 1. re-prime according to instructions 2. air leaks 2. check all connections on suction line 3. leaking foot valve 3. replace foot valve *pump has lost prime through: in installation already in use: 1. air leaks 1. check all connections on suction line and shaft seal 2. water level below suction of pump 2. lower suction line into water and re-prime. if receding water level in well exceeds suction lift, a deep well pump is needed impeller is plugged clean impeller; see maintenance check valve or foot valve is stuck replace check valve or foot valve in closed position pipes are frozen thaw pipes. bury pipes below frost line. heat pit or pump house. foot valve and/or strainer are raise foot valve and/or strainer above well bottom buried in sand or mud pump does not water level in well is lower than a deep well jet pump may be needed (over 20 ft. to water) deliver water to full estimated capacity (also steel piping (if used) is corroded or replace with plastic pipe where possible, otherwise with new steel pipe check point 3 limed, causing excess friction immediately above) offset piping is too small in size use larger offset piping *(notice: check prime before looking for other causes. unscrew priming plug and see if there is water in priming hole.)
repair parts 12 ? not illustrated. * model ds3hhg3-01 uses base c4-82. 3621 1199spc 1 2 3 13 14 15 12 7a 11 5 6 7 8 4 9 6a 10 model number ds3he-01 DS3HF-01 ds3hg-01 ds3hhg-01 key part ds3he3-01 ds3hf3-01 ds3hg3-01 ds3hhg3-01 no. description qty. 1 hp 1-1/2 hp 2 hp 2-1/2 hp 1 motor, 115/230v, 1 phase 1 j218-596pkg j218-601pkg j218-883apkg j218-628a 1 motor, 230/460v, 3 phase 1 ap100el ap100fl ap100gl ap100g5l 2 water slinger 1 17351-0009 17351-0009 17351-0009 17351-0009 3 seal plate 1 c3-155 c3-155 c3-117 c3-117 4 gasket - seal plate 1 c20-86 c20-86 c20-87 c20-87 5 shaft seal 1 u109-6a u109-6a u109-6a u109-6a 6 impeller (1 phase) 1 c105-92pkb c105-92pc c105-214pda c105-214pa 6 impeller (3 phase) 1 c105-92pkba c105-92pca c105-214pda c105-214pa 6a impeller screw (1 phase) 1 c30-14ss c30-14ss 6a impeller screw (3 phase) 1 c30-14ss c30-14ss c30-14ss c30-14ss 7 diffuser 1 c101-276p c101-276p c101-182 c101-182 7a screw 10-24 x1 lg hex head 2 u30-696ss u30-696ss 7a machine screw 8-32x7/8 lg. 2 u30-53ss u30-53ss 8 diffuser ring 1 c21-10 c21-10 c21-2 c21-2 9 pump body assembly 1 c76-67 c76-67 c76-68 c76-68 10 plug 1/4 npt hex head 1 u78-941zpv u78-941zpv u78-941zpv u78-941zpv 11 base 1 c4-82 c4-82 c4-82 c4-82a* 12 3/8-16x 1-1/4 lower capscrew 2 u30-75zp u30-75zp u30-75zp u30-75zp 13 3/8-16x 1 upper capscrew 2 u30-74zp u30-74zp u30-74zp u30-99ss 14 motor pad 1 c35-5 c35-5 c35-5 c35-5 15 capscrew 3/8-16x3/4 lg 6 u30-72zp u30-72zp 15 capscrew 5/16-18x3/4 lg. 8 u30-60zp u30-60zp ? lockwasher 3/8 2 u43-12zp u43-12zp u43-12zp u43-12zp ? nut, 3/16-18 hex head 2 u36-37zp u36-37zp u36-37zp u36-37zp


▲Up To Search▲   

 
Price & Availability of DS3HF-01

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X